1. Application |
|
-
High rellability by S.M.T & TQC.(Surface Mounting Technology)
-
High Isolation over than 50MQ/500VDC
-
High dielectric over than 2.5KV
-
Low enable current less than 7.5mA/12VDC CMOSIC or TTL Compatible.
-
Low EMI/EFI& surge by Zeero cross Trigger Method.
-
High surge current duration,over 10 Times of rated current/one cycle.
-
High surge voltage duration by snubber circuit.
|
|
2. Guiding of Model
|
|
|
|
3. Control Method |
|
Zero Cross Trigger Method
Output TURN ON or TURN OFF only on zero cross point of sine wave,may avoid surge or EMI/RFI occurring.
Specially suited to control resistive,capacitive and Non-saturated inductive loads |
|
|
Variable resistance control method
Power output is controlled by the trigger angle of triac with variable resister 250KQ/110VAC,500KQ/220VAC
|
|
|
4. Application Hints |
|
Input |
NPN |
Output |
NO |
Input |
NPN |
Output |
NO |
Input |
NPN |
Output |
NO |
|
|
|
Input |
NPN |
Output |
NO |
Input |
NPN |
Output |
NO |
Input |
NPN |
Output |
NO |
|
|
|
|
|
Type
|
Standard type |
High voltage type |
PCB type |
Model |
PN-10DA |
PN-25DA |
PN-40DA |
PN-25DA-H |
PN-40DA-H |
PN-05DA |
Rated load current |
10A |
25A |
40A |
25A |
40A |
5A |
Input voltage |
4-32VDC |
Min. on/off voltage |
ON>2.4V, OFF<1.0V |
Trigger current |
7.5mA/12V |
Control method |
Zero cross trigger |
Operating voltage |
24-380VAC |
90-480VAC |
24-380VAC |
Min. black voltage |
600VAC |
Voltage drop |
1.6V/25℃ |
Max. durated current |
135A |
275A |
410A |
275A |
410A |
135A |
Leakage current |
3.0mA |
3.0mA |
5.0mA |
5.0mA |
5.0mA |
3.0mA |
Response time |
ON<10ms/OFF<10ms |
Dielectric strength |
Over 2.5KVAC/ 1min. |
Isolation strength |
Over 50M/500VDC |
Operating temperature |
-20℃~+80℃ |
Housing Material |
Intensive ABS |
Weight |
105G |
|
|